# 25ka Surge Arrester 25GR 4P Type 1 Specifications and Features

## Introduction to Surge Protection

Surge protection devices play a crucial role in safeguarding electrical systems from voltage spikes and transient overvoltages. The 25ka Surge Arrester 25GR 4P Type 1 represents a high-performance solution designed for robust protection in demanding electrical environments.

## Key Specifications

Technical Parameters

The 25ka Surge Arrester 25GR 4P Type 1 offers exceptional protection capabilities with the following specifications:

  • Nominal Discharge Current (In): 25kA
  • Maximum Discharge Current (Imax): 50kA
  • Voltage Protection Level (Up): ≤ 2.5kV
  • Rated Voltage (Uc): 320V AC
  • Response Time: < 25ns
  • Number of Poles: 4P (4-pole configuration)
  • Protection Class: Type 1 (according to IEC 61643-11)

## Design Features

Construction and Performance

The 25GR model incorporates several advanced design features that enhance its performance and reliability:

  • Spark gap technology for superior surge protection
  • Thermal disconnector for safe operation
  • Visual status indication for easy monitoring
  • Robust housing with IP20 protection rating
  • Compact design for space-efficient installation
  • High-quality materials for long service life

## Application Areas

Where to Use the 25GR 4P Type 1

This surge arrester is particularly suitable for:

  • Main distribution boards in commercial buildings
  • Industrial power distribution systems
  • Telecommunication facilities
  • Data centers and server rooms
  • Medical facilities with sensitive equipment
  • Any application requiring Type 1 surge protection

## Installation Considerations

Mounting and Wiring

For optimal performance, consider these installation guidelines:

  • Install at the service entrance or main distribution panel
  • Ensure proper grounding with low impedance connections
  • Follow local electrical codes and regulations
  • Use appropriate cable sizes for connections
  • Maintain proper clearance around the device
  • Consider combining with Type 2 and Type 3 protectors for comprehensive protection

## Maintenance and Monitoring

Ensuring Continued Protection

To maintain optimal performance of your 25ka Surge Arrester:

  • Regularly inspect the visual status indicator
  • Perform periodic testing according to manufacturer recommendations
  • Replace the unit if it has absorbed significant surge energy
  • Keep records of lightning events and protection device status
  • Consider professional inspection after major electrical events

## Compliance and Standards

Certifications and Approvals

The 25GR 4P Type

Leave a Reply